Intelligent Residual Current Circuit Breaker RCCB With LCD Display

Brand Name : Tengen
Model Number : TGM2E2-Y
Certification : GB14048.2
Place of Origin : Zhejiang, China (Mainland)
MOQ : 1
Price : negotiable
Supply Ability : 80000 Pieces per Month
Delivery Time : 8-15 Work Days
Packaging Details : Standard package or according to customer's requirements
Rated current shell frame level(A) : 125A,250A,400A,800A
Poles : 3P+N
Limit Non-Actuating Time (mm) : △t: 0.06 (2I△n)
Rated Residual Operation Current I△no : 50%I△n
Rated Residual Current Breaking Time (s) : 0.3s/0.5s(I△n)
Automatic Re-Closing Time (s) : 20~60
Flashover Distance (mm) : ≤50
Contact Now

Intelligent Residual Current Circuit Breaker RCCB with LCD display


TGM2E2-□Y series residual current circuit breaker (Hereinafter referred to as “circuit breaker”) is the scientific and technological innovation type of products developed by our company according to the power-usage environment of urban and rural power grids of our nation. It combines residual current circuit breaker with moulded case circuit breaker. It is suitable for the circuit with AC 50Hz, 400V rated working voltage, 1000V rated insulation voltage and rated current to 800A power supply system of 3 poles four lines neutral grounding. It can provide indirect protection for body electric shock, and it also can prevent the fire caused by grounding fault current from damage of equipment insulation. It can protect the circuit or power equipment from overload, short-circuit, over-voltage, under-voltage and loss of phase, etc.


Basic Data Sheet
Frame Size Rated Current125250400800
Poles3P+N3P+N3P+N3P+N
Frequency(Hz)50505050
Rated Working Voltage Ue (V)AC400AC400AC400AC400
Rated Insulation Voltage Ui (V)AC800AC1000AC400AC400
Rated Impulse Withstand
Voltage Uimp (kV)
8888
Rated Current In (A)125250400630800

Rated Setting Current Irl

(A)

50/63/80/
100/125
Adjustable
(Default 125)

100/125/

140/160/

180/200/

225/250 Adjustable
(Default 250)

200/225/250/
315/350/400
Adjustable
(Default 400)

315/350/

400/500/

630
Adjustable
(Default 630)

400/500/

630/700/

800
Adjustable
(Default 800)

Rated Limited Short Circuit
Breaking Capacity Icu (kA)
50506565
Rated Operating Short Circuit
Breaking Capacity Ics (kA)
35354250
Rated Residual Short-Circuit Connecting(Breaking) Capacity I△m (kA)25%Icu25%Icu25%Icu25%Icu
Rated Short-Time Withstand Current Icw(kA/s)1.5kA/1s3kA/1s5kA/1s10kA/1s
Rated Residual Operation Current
I△n

50/100/200/300/

400/500/
600/800mA
MCU Automatic Tracking or Manual Setting

50/100/200/
300/400/500/
600/800mA
MCU Automatic Tracking or Manual Setting
50/100/200/
300/400/500/
600/800/1000mA
MCU Automatic Tracking or Manual Setting
100/200/300/
500/800/1000mA
MCU Automatic Tracking or Manual Setting
Residual Current Operation PerformanceAC TypeAC TypeAC TypeAC Type
Limit Non-Actuating Time (mm)△t: 0.06 (2I△n)
Rated Residual Operation Current I△no50%I△n50%I△n50%I△n50%I△n
Rated Residual Current Breaking Time (s)0.3s/0.5s(I△n)
Automatic Re-Closing Time (s)20~6020~6020~6020~60
Usage TypeA TypeA TypeA TypeA TypeA Type
Flashover Distance (mm)≤50≤50≤100≤100
Service EnduranceMechanical1500100010001000
Electrical8500700040004000
Accessories Information
Auxiliary Contact/□(1NO 1NC Optional)□(2NO 2NC Optional)/
  1. Normal Working Condition and Installation Condition
    1. No conductive dust, no corrosive gas, no flammable and explosive gas and no rain and snow in where installed.
    2. Altitude ≤2000m.
    3. Ambient temperature: -5℃~+40℃.
    4. Humidity: The relative humidity is not over 50% when the highest ambient temperature is 50℃. The humidity is higher when the

temperature is lower. The max relative humidity is not over 90% when it is the most humid month, and at the same time the min temperature is not over 25℃ this month. Condensation caused by the change of temperature will influence the application of the products.

  1. Pollution Grade: third grade
  2. Installation Type: Ⅲ.
  3. External field: magnetic field around the installation place shall not over 5 times of geomagnetic field.

  1. Classification and Function of Circuit Breaker

FunctionIntelligent Type
(Basic Type)
Communication Type
Protection
Function
Overload Protection
Short-Circuit Protection
Residual Current Protection
Auto Re-Closing
Loss of Phase
Over-Voltage Protection
Under-Voltage Protection
Measurement
Display
Circuit Residual Current
3 Phase Working Voltage
3 Phase Working Current
Performance
Setting
Rated Residual Operation Current
Overload Long-Time Delay
Short-Circuit Short-Time Delay
Short-Circuit Instant
Over-Voltage Protection Value
Under-Voltage Protection Value
Time, Date
Protection Input and Exit
Info Storage,
Consult and Display
Residual Current Operation
Other Operation
Communication Function (Optional)RS-485 
  1. Operation Value Setting Range

Table 1

ParameterFrame Size Rated CurrentRated CurrentSetting ValueDefault Setting Value
Operation Setting Value
Irl (A)
12512550, 63, 80, 100, 125125
250250100, 125, 140, 160, 180,
200, 225, 250
250
400400200, 225, 250, 315, 350, 400400
800630315, 350, 400, 500, 630630
800400, 500, 630, 700, 800800
Delay Time Setting Value3, 6, 8, 10, 12, 16, 18, OFF12
  1. Operation Performance

Table 2

Ambient TemperatureCurrent NameSetting Multiple of CurrentTripping Time
+40℃Arranged No Tripping Current1.05Irl≥2h
Arranged Tripping Current1.30Irl<1h

  1. Short-Circuit Short-Time Delay

Short-circuit short-time delay protection prevent the resistance short-circuit of power distribution system, and tripping delay is to achieve the selective protection


  1. Relative Parameter Setting of Short-Circuit Short-Time Delay Protection

Table 3

Parameter SettingDefault Setting Value
Short-Time Delay Operation Current
Setting Value Ir2
2Ir1, 2.5Ir1, 3Ir1, 4Ir1, 5Ir1, 6Ir1,
7Ir1, 8Ir1, 10Ir1, 12Ir1
6Ir1
Short-Time Delay Time
Setting Value ts
0.1s, 0.2s, 0.3s, 0.4s, 0.6s, 0.8s, 1.0s, OFF0.4s

  1. Operation Performance of Short-Circuit Short-Time Delay Protection

Table 4

PerformanceMultiple of CurrentTripping PerformanceAllowed Time-Delay Error
No Operation Performance≤0.9Ir2No Operation±15%
Operation Performance>1.15Ir2Time-Delay Operation

  1. Instant Protection
    1. Relative Parameter Setting of Short-Circuit Instant Protection

Table 5

Parameter SettingDefault Setting Value
Instant Operation Current
Setting Value Ir3
4Ir1, 6Ir1, 7Ir1, 8Ir1, 10Ir1, 12Ir1, 13Ir1, 14Ir1, OFF10Ir1

  1. Operation Performance of Short-Circuit Instant Protection

Table 6

PerformanceMultiple of Current(I/Ir3)Tripping PerformanceAllowed Time-Delay Error
No Operation Performance≤0.85No Operation 
Operation Performance>1.15Instant Operation<0.2s

  1. Residual Current Protection Performance
    1. Gears Setting Range

Table 7

ParameterSetting ValueDefault Setting Value
Residual Operation Current I△n50, 100, 200, 300, 400, 500, 600, 800, 1000, Auto500mA

  1. Operation Performance

Table 8

ParameterPerformance
Residual Current Operation PerformanceStandard Type/S Type
Rated Residual No Operation Current0.5I△n
Limit Non-Actuating Time△t:0.06s(2I△n)
Residual Current Operation Time0.3s/0.5s3.jpg(I△n)

Product Tags:

rccb circuit breaker

      

residual current operated circuit breaker

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Intelligent Residual Current Circuit Breaker RCCB With LCD Display Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Tengen International Industrial Limited
Subject:
Message:
Characters Remaining: (0/3000)